The DC/AC Clamp Meter is a True RMS digital electrical measuring instrument designed for testing both direct and alternating current in maintenance, inspection and troubleshooting environments. EMTOP model EDMR762002 provides 4000-count measurement capability, DC/AC current ranges up to 400 A and DC/AC voltage ranges up to 600 V. It also measures resistance and capacitance and includes NCV detection, diode testing, data hold, a built-in flashlight, low-battery indication and automatic power-off.IndustrialAdda supplies the EMTOP DC/AC Clamp Meter across Delhi NCR, with eligible Pan-India supply support subject to availability and order requirements.
The EMTOP EDMR762002 DC/AC Clamp Meter is a True RMS 4000-count testing instrument used where technicians need to measure both DC and AC current as well as DC/AC voltage, resistance and capacitance. It is relevant to industrial electrical maintenance, automotive electrical work, battery-powered systems, HVAC service and general troubleshooting.
Its ability to measure both DC and AC current is the main distinction in the supplied product specification.
The supported current ranges are:
The voltage ranges are:
This makes the meter relevant to environments where technicians may encounter alternating-current systems as well as direct-current circuits.
The supplied application information includes:
The clamp design allows current measurement around a conductor, while additional diagnostic functions broaden the meter's usefulness beyond current alone.
Potential buyers may include:
For accurate procurement, buyers should identify the instrument as EMTOP EDMR762002.
EDMR762002 combines DC/AC current measurement with voltage, resistance and capacitance testing in one True RMS meter. Supporting functions such as NCV detection, diode testing, data hold and a built-in flashlight make the unit relevant to technicians performing electrical diagnostics across varied work environments.
True RMS 4000-Count Display
The meter is specified with a True RMS 4000-count display.
This is a key identifying characteristic when procurement teams compare the requested model with existing instrument specifications.
DC/AC Current Measurement
The meter measures both direct and alternating current across the following supplied ranges:
4 A / 40 A / 400 A
This gives EDMR762002 a different application profile from AC-only clamp meters.
For technicians working with automotive, battery-powered or DC equipment, DC current measurement can be particularly relevant.
DC/AC Voltage Measurement
Voltage ranges are specified as:
400 mV / 4 V / 40 V / 600 V
The instrument can therefore support both low-voltage and higher-voltage measurements within the provided ranges.
Resistance Measurement
Available resistance ranges are:
400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ
Resistance measurement can be useful during suitable electrical troubleshooting and continuity-related diagnostic work.
Capacitance Measurement
The supplied capacitance ranges are:
4 nF / 40 nF / 400 nF / 4 µF / 40 µF / 400 µF / 4 mF
This provides additional diagnostic capability within the meter.
NCV Detection
EDMR762002 includes Non-Contact Voltage detection.
NCV can assist technicians in identifying the presence of voltage without direct contact.
It should be used as a supporting detection function alongside proper electrical safety procedures.
Diode Test
A diode test function is included.
This allows the instrument to support suitable component-level diagnostic checks where diode testing is required.
Data Hold
The Data Hold feature allows the displayed measurement to be retained.
This can help when technicians need to record a reading after moving away from the measurement point.
Built-In Flashlight
The meter includes a built-in flashlight.
This can be useful in electrical panels, equipment enclosures or other areas with limited visibility.
Battery and Power Management
The meter uses:
2 × LR03 AAA batteries
The supplied package includes these batteries.
Additional power-related functions include:
EDMR762002 is suited to electrical and maintenance environments where technicians need both AC and DC current measurement. Typical applications include automotive diagnostics, battery systems, electrical panels, machinery, power supplies, HVAC equipment, workshops and facility maintenance.
Automotive Electrical Diagnostics
Automotive electrical systems frequently involve direct current.
Technicians may need to investigate current flow, voltage levels or electrical faults in vehicle circuits and battery-powered systems.
Because EDMR762002 supports DC current measurement up to 400 A, it can be considered for suitable automotive electrical testing where its measurement range matches the task.
For workshops, procurement teams should verify whether the supplied ranges align with the vehicles and electrical systems being serviced.
Battery-Powered Equipment
Battery-powered machinery and equipment rely on DC electrical systems.
Maintenance personnel may need to check current draw, voltage or related circuit conditions during troubleshooting.
The DC-current capability of EDMR762002 makes the model relevant to such applications.
Electrical Panel Testing
Industrial electrical panels typically involve alternating-current circuits.
The same meter can support AC current and AC voltage measurement while also providing resistance and capacitance functions for appropriate diagnostic tasks.
This gives maintenance teams a multi-function instrument for suitable panel work.
Power Supply Inspection
Power supplies may involve both AC input and DC output.
A meter capable of measuring both DC and AC electrical values can be useful when technicians need to examine different parts of the system during troubleshooting.
EDMR762002 provides both current and voltage functions for these types of environments.
Industrial Machinery
Industrial machines can contain AC mains circuits, DC control circuits or battery-supported components.
The combination of AC/DC current and AC/DC voltage measurement can therefore be relevant during appropriate inspection and maintenance activities.
The meter's resistance, capacitance and diode functions provide additional diagnostic options.
HVAC Service
HVAC systems can require current, voltage, resistance and capacitance measurements during maintenance.
EDMR762002 can support suitable electrical diagnostic work where the technician needs these functions within the meter's specified ranges.
Facility Maintenance
Facility maintenance teams often work across lighting, motors, wiring, controls and electrically powered equipment.
A multi-function clamp meter can support varied maintenance requirements where both AC and DC testing may be encountered.
EMTOP EDMR762002 is a True RMS 4000-count DC/AC Clamp Meter with current measurement up to 400 A and voltage measurement up to 600 V. The meter also supports resistance, capacitance, diode testing and NCV detection and operates on two LR03 AAA batteries.
Specification |
Product Detail |
|
Product Name |
DC/AC Clamp Meter |
|
Brand |
EMTOP |
|
Model Number |
EDMR762002 |
|
Product Category |
Electrical Testing & Measuring Instruments |
|
Product Type |
True RMS Digital DC/AC Clamp Meter |
|
Display |
True RMS 4000 Counts |
|
DC/AC Current Range |
4 A / 40 A / 400 A |
|
DC/AC Voltage Range |
400 mV / 4 V / 40 V / 600 V |
|
Resistance Range |
400 Ω / 4 kΩ / 40 kΩ / 400 kΩ / 4 MΩ / 40 MΩ |
|
Capacitance Range |
4 nF / 40 nF / 400 nF / 4 µF / 40 µF / 400 µF / 4 mF |
|
Data Hold |
Yes |
|
Built-In Flashlight |
Yes |
|
NCV Detection |
Yes |
|
Diode Test |
Yes |
|
Low Battery Indication |
Yes |
|
Automatic Power-Off |
Yes |
|
Power Supply |
2 × LR03 AAA Batteries |
|
Packaging |
Double Blister |
|
Package Contents |
1 × DC/AC Clamp Meter + 2 × LR03 AAA Batteries |
No accuracy specification, jaw opening, CAT rating, frequency range, IP rating, dimensions, weight or certification has been supplied in the source information.
Those details should be verified separately where required for procurement.
EDMR762002 is relevant where maintenance teams need one clamp meter capable of handling both direct and alternating current. Its broader measurement set, together with NCV, diode testing and data hold, makes it suitable for technicians working across mixed electrical environments rather than AC-only systems.
Both DC and AC Current Measurement
The ability to measure both current types is the most important supplied functional difference.
This supports applications involving battery systems, automotive electrical circuits and AC industrial systems.
Voltage Measurement up to 600 V
The supplied DC/AC voltage range extends to 600 V.
This gives buyers a clearly defined maximum voltage reference for product evaluation.
Additional Diagnostic Functions
Resistance, capacitance and diode testing expand the meter's usefulness beyond current and voltage.
Non-Contact Voltage Detection
NCV provides a supporting electrical-detection function for suitable field checks.
Portable Battery-Powered Operation
The instrument operates using two AAA batteries, which are included in the package.
Clear Model Reference for Repeat Procurement
The model number EDMR762002 allows maintenance and MRO teams to specify the same instrument consistently in future procurement requests.
IndustrialAdda supplies EMTOP EDMR762002 DC/AC Clamp Meter for B2B electrical, automotive, maintenance and industrial procurement requirements. Buyers can submit model-specific requirements for sourcing, quotation assistance, product verification and availability confirmation.
IndustrialAdda acts as the supplier for this product.
No claim is made that IndustrialAdda manufactures, develops or designs the EMTOP clamp meter.
B2B support can include:
For larger maintenance or project requirements, buyers can submit EDMR762002 together with other electrical instruments or industrial products in a consolidated BOM or requirement sheet.
IndustrialAdda primarily supports industrial customers across Delhi NCR from New Delhi. Eligible EDMR762002 requirements may also be supported in other parts of India depending on product availability, order quantity, delivery location and commercial conditions.
Delhi NCR Supply
Primary B2B coverage includes:
The meter may be required by automotive workshops, electrical contractors, manufacturing plants, HVAC companies and facility maintenance departments.
Businesses searching for a DC/AC Clamp Meter supplier in Delhi NCR should provide the exact EDMR762002 model number when requesting commercial information.
Pan-India Supply Capability
Eligible requirements can also be assessed for delivery beyond Delhi NCR.
Pan-India supply depends on:
No fixed stock status or delivery timeline has been provided.
Both should be confirmed during the quotation stage.
To request an EDMR762002 quotation, buyers should provide IndustrialAdda with the exact model number, required quantity, intended electrical application and delivery destination. Procurement teams should also mention any mandatory testing range, documentation or project requirement before finalizing the order.
A useful RFQ should include:
1. Exact Product
DC/AC Clamp Meter – EMTOP EDMR762002
2. Quantity
Required number of meters
3. Application
Automotive, battery systems, electrical panels, machinery, HVAC, workshop or facility maintenance
4. Technical Requirement
Any mandatory measurement or company specification
5. Delivery Destination
City and PIN code
6. Commercial Request
Quotation, availability and delivery confirmation
For project or MRO purchasing, buyers can also attach a BOM, model schedule or broader electrical-testing requirement.
EDMR762002 measures both DC and AC current, with supplied current ranges of 4 A, 40 A and 400 A. This makes it relevant to applications such as automotive electrical systems, battery-powered equipment and industrial systems where both direct and alternating current may need to be checked.
The supplied DC/AC voltage ranges are 400 mV, 4 V, 40 V and 600 V. Buyers should confirm that these ranges match the intended electrical system before procurement and should not assume any higher voltage capability than the provided specification.
Yes. The supplied capacitance ranges are 4 nF, 40 nF, 400 nF, 4 µF, 40 µF, 400 µF and 4 mF. This function can support suitable electrical troubleshooting where capacitance measurement is part of the diagnostic process.
Yes. The meter includes NCV, or Non-Contact Voltage detection. This can assist technicians in detecting the presence of voltage without direct electrical contact. NCV should be used according to appropriate electrical safety procedures and should not replace required verification methods.
For procurement of EMTOP DC/AC Clamp Meter EDMR762002, send IndustrialAdda:
IndustrialAdda can assist with model verification, quotation coordination and eligible supply requirements across Delhi NCR and other Indian locations, subject to availability and order conditions. Send your product requirement for commercial confirmation.
| Display | TRUR RMS 4000 counts |
|---|---|
| DC/AC Current | 4A/40A/400A |
| DC/AC Voltage | 400mV/4V/40V/600V |
| Resistance | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ |
| Capacitance | 4nF/40nF/400nF/4uF/40uF/400uF/4mF |
| Data Hold | Data Hold |
| Flashlight | Flashlight |
| NCV | NCV |
| Diode test | Diode test |
| Low battery indication | Low battery indication |
| Auto power off | Auto power off |
| Batteries | With 2pcs LR03 AAA batteries |
| Packaging | Packed by double blister |
IndustrialAdda supplies EmTop EDMR762002 for B2B requirements across Delhi NCR, including Delhi, Noida, Gurgaon, Ghaziabad and Faridabad. Buyers should provide the model number, quantity and delivery location when requesting quotation and availability information.
Automotive electrical systems are included among the supplied applications. Because the instrument measures DC current as well as DC voltage, it can be considered for suitable automotive electrical testing where its specified measurement ranges match the technician's requirement.
Businesses can submit quantity-based procurement enquiries for EDMR762002. IndustrialAdda can evaluate workshop, industrial maintenance, contractor and MRO requirements based on requested quantity, product availability and delivery location. No minimum order quantity has been supplied.
Eligible Pan-India requirements may be supported depending on product availability, order quantity, destination and specific order conditions. Buyers outside Delhi NCR should provide the exact EDMR762002 model number, number of units required and delivery city or PIN code.
Fill in your details and our B2B team will contact you shortly.